Keep your hospital equipment functioning properly with the Tripp Lite OmniSmart 350HG UPS. It offers protection from brown outs, power surges and full loss of power. This medical-grade ups includes a built-in line interactive voltage regulation and intelligent monitoring and unattended shutdown capability.
Output Output Volt Amp Capacity (VA) : 330
Output Watt Capacity (watts) : 225
Nominal Output Voltage(s) Supported : 120v
Frequency compatibility : 60 Hz
Output voltage regulation (line mode) : -18%, +8%
Output voltage regulation (Battery mode) : +/- 5%
Built-in UPS output receptacles : 4 5-15R outlet(s)
Output receptacle details : Hospital grade output receptacles
Output AC waveform (AC mode) : Sine wave
Output AC waveform (battery mode) : PWM sine wave Input Rated input current (at maximum load) : 2.3A
Nominal Input Voltage(s) Supported : 120V AC
UPS input connection type : 5-15P-HG
Input circuit breaker : 3.5A
UPS Input cord length (ft.) : 6
UPS Input cord length (m) : 1.8
Recommended Electrical Service : 15A 120V Battery Full load runtime (minutes) : 18 min. (225w)
Half load runtime (minutes) : 46 min. (115w)
DC system voltage (VDC) : 12
Battery recharge rate (included batteries) : Less than 4.5 hours from 10% to 90%
Replacement battery cartridge (internal UPS battery replacement) : RBC52 (quantity 2)
Battery Access : Battery access door
Battery replacement description : Hot-swappable, user replaceable batteries Voltage Regulation Voltage regulation description : Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89
Undervoltage correction : Input voltages between 89 and 107 are boosted by 14% LEDs Alarms and Switches LED Indicators : 4 LEDs indicate line power, battery power, overload and battery low/replace status
Alarms : Audible alarm indicates power-failure and low-battery conditions
Alarm cancel operation : Power-fail alarm can be silenced using alarm-cancel switch, once silenced, alarm will re-sound to indicate low-battery status
Switches : 2 Switches control off/on power status and alarm-cancel/self-test operation Surge/Noise Suppression UPS AC suppression response time : Instantaneous
UPS Dataline suppression : 2 line TEL / DSL protection
EMI / RFI AC noise suppression : Yes Isolation Output isolation transformer : Hospital grade load isolation transformer Physical Installation form factors supported with included accessories : Tower
Primary form factor : Tower
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) : 10.8 x 5.2 x 7.2
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) : 27.3 x 13.3 x 18.4
UPS / Power Module weight (lbs) : 25
UPS / Power Module weight (kg) : 11.4
UPS Shipping dimensions (height x width x depth / inches) : 14 x 8.5 x 11
UPS Shipping dimensions (height x width x depth / cm) : 35.6 x 21.6 x 27.9
Shipping weight (lbs) : 28
Shipping weight (kg) : 12.7
UPS housing material : PVC Environmental Operating Temperature Range : +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range : +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity : 0 to 95%, non-condensing
AC mode BTU / hr. (full load) : 48.8
Battery mode BTU / hr. (full load) : 215.8 Communications Communications interface : DB9 Serial
PowerAlert software : Free download from www.tripplite.com
Communications cable : DB9 serial cable included