Protects connected mission-critical equipment against damage, downtime and data loss due to blackouts, brownouts, power surges and line noise.
- UPC Code: 037332118820
- UPS Type: Line-Interactive
- Input Phase: Single-Phase
- Rated input current (Maximum Load): 9A
- Nominal Input Voltage(s) Supported: 120V AC
- UPS Input Connection Type: 5-15P
- Input Circuit Breakers: 15A
- Recommended Electrical Service: 15A 120V
- Input Cord Length (ft.): 10
- Output Capacity (VA): 1000
- Output Capacity (kVA): 1
- Output Capacity (Watts): 800
- Output Capacity (kW): 0.8
- Power Factor: 0.8
- Nominal Voltage Details: 120v nominal output in battery mode
- Frequency Compatibility: 60 Hz
- Output Voltage Regulation (Line Mode): -21%, +8%
- Output Voltage Regulation (Battery Mode): +/- 5%
- Load Management Receptacles: Two switchable single-outlet 5-15R load banks
- Output AC Waveform (AC Mode): Sine wave
- Output AC Waveform (Battery Mode): Pure Sine wave
- Nominal Output Voltage(s) Supported: 110V; 115V; 120V
- Output Receptacles: (6) 5-15R
- Individually Controllable Load Banks: Yes
- Battery Type: Valve Regulated Lead Acid (VRLA)
- Runtime Full Load (min.): 4 min. (800W)
- Runtime Half Load (min.): 14 min. (400W)
- DC System Voltage (VDC): 24
- Battery Recharge Rate (Included Batteries): 4.5 hours from 10% to 90% (typical, full load discharge)
- Battery Access: Front panel battery access door
- Internal UPS Replacement Battery Cartridge: RBC69-1U
- Battery Replacement Description: Hot-swappable, user replaceable batteries
- Voltage Regulation Description: Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
- Overvoltage Correction: Input voltages between 128 and 147 are reduced by 12%
- Undervoltage Correction: Input voltages between 83 and 107 are boosted by 14%
- Switches: 2 Switches control off/on power status and alarm-cancel/self-test operation
- Alarm Cancel Operation: Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
- Audible Alarm: Audible alarm indicates power-failure, overload and low-battery conditions
- LED Indicators: 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
- UPS AC Suppression Joule Rating: 450
- EMI / RFI AC Noise Suppression: Yes
- AC Suppression Response Time: Instantaneous
- Primary Form Factor: Rackmount; Vertical
- Rack Height: 1U
- Cooling Method: Fan
- Included Mounting Accessory Description: Included mounting brackets provide front-rail installation in 2 or 4 post racks; For additional stability in 4 post racks, consider optional 4 post mounting accessories 4POSTRAILKIT1U & 4POSTRAILKITWM
- Installation Form Factors Supported with Included Accessories: 2 post 19 inch rackmount; 2 post front mount; 4 post 19 inch rackmount
- Installation Form Factors Supported with Optional Accessories: Vertical Mount Enclosures ( SRWF5U36 , SRWF5U , SRWF10UMOD )
- Minimum Required Rack Depth (inches): 20
- Optional Mounting Accessory Notes: Optional 4POSTRAILKITWM enables installation in 4-port short-depth racks from 14.5 to 23.5 inches (368 to 597mm); Optional 4POSTRAILKIT1U enables installation in 4-post full-depth racks from 20.5 to 36 inches (521 to 914mm)
- Primary UPS Depth (mm): 425
- Primary UPS Height (mm): 44
- Primary UPS Width (mm): 445
- Shipping Dimensions (hwd / in.): 5.30 x 21.30 x 22.90
- Shipping Weight (lbs.): 34.75
- UPS Housing Material: Steel
- UPS Power Module Dimensions (hwd, in.): 1.75 x 17.5 x 16.75
- UPS Power Module Weight (kg): 14.51
- UPS Power Module Weight (lbs.): 32
- Unit Weight (lbs.): 32.0000
- Operating Temperature Range: 32r to 104rF (0r to 40rC)
- Storage Temperature Range: 5r to 122rF (-15r to 50rC)
- Relative Humidity: 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load): 39
- AC Mode Efficiency Rating (100% Load): 99%
- Audible Noise: 45 dBA maximum, front side 1m
- Network Management Cards: SNMPWEBCARD; TLNETCARD ; WEBCARDLX
- Network Monitoring Port Description: Supports detailed monitoring of UPS and site power conditions
- PowerAlert Software: For local monitoring via the UPSrs built-in communications ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
- Communications Cable: USB and DB9 cabling included
- WatchDog Compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications
- Network Management Card Description: Network management card optional
- Communications Interface: DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB
- Transfer Time: 5 milliseconds AC to DC; 1 millisecond DC to AC
- Low Voltage Transfer to Battery Power (Setpoint): 83
- High Voltage Transfer to Battery Power (Setpoint): 147
- Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
- High Availability UPS Features: Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection
- Green Energy-Saving Features: Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
- Grounding Details: Back panel grounding lug
- UPS Applications: Large Network; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality
- Product Certifications: CSA (Canada); NOM (Mexico); UL 1778
- Product Compliance: RoHS; FCC Part 15 Class A (USA)
- Product Warranty Period (Worldwide): 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty.
- Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance